Welcome To China Professional Cable Manufacturer - HuaDong Cable Group

Home > Logging Cable > Monoconductor >

Monoconductor

1N10

1/10” (2.56 mm) MONOCONDUCTOR 1N10

1/10” (2.56 mm) MONOCONDUCTOR 1N10 PROPERTIES


Cable Diameter 0.101” +0.004” -0.002” (2.56mm + 0.10mm -0.05mm)
Minimum Sheave Diameter 6” (15 cm)
Cable Stretch Coeffcient 13.1 ft/Kft/Klbs (14.72 m/Km/5KN)

 

1/10” (2.56 mm) MONOCONDUCTOR 1N10 ELECTRICAL


Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 24
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance 22.0 Ω/Kft (72.2 Ω/Km)

 

1/10” (2.56 mm) MONOCONDUCTOR 1N10 MECHANICAL


Cable Breaking Strength
Ends Fixed
1,000 lbs (4.4 KN) Nominal
Maximum Suggested Working Tension 500 lbs (2.2 KN)
Number and Size of Wires
Inner Armor 12 x 0.0140” (0.356 mm)
Outer Armor 18 x 0.0140” (0.356 mm)
Average Wire Breaking Strength
Inner Armor 42 lbs (0.19 KN)
Outer Armor 42 lbs (0.19 KN)

Cable Type  Core Description  Cable Weight
1N10RP  Temp
Rating
°F
°C
Plastic
Type
Insulation
Thickness
in
mm
Copper
Construction
in
mm
Res
Typical
Ω/Kft
Ω/Km
Cap.
Typical
pf/ft
pf/m
O.D.
Each
in
mm
in
Air
in
H2O
lbs/Kft
Kg/Km
300
149
Poly  0.012
0.305
7x0.0085
7x0.216
21.0
69.0
51
167
0.049
1.244
19
28
15
23

The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F.
Voids in the copper strand are flled with a water-blocking agent to reduce water and gas migration.
SUPERSEAL, a special pressure seal agent, is applied between armor layers.
The temperature rating assumes a normal gradient for both temperature and weight.
All values shown are nominal or typical values.

Any cable inquiry please feel free to contact us.

Send Email