Welcome To China Professional Cable Manufacturer - HuaDong Cable Group

Home > Logging Cable > 7-Conductor >

7-Conductor

7H47–EHS

0.474” (12.0mm) 7-CONDUCTOR EXTRA HIGH STRENGTH 7H47–EHS

0.474” (12.0mm) 7-CONDUCTOR, EXTRA HIGH STRENGTH 7H47–EHS PROPERTIES


Cable Diameter 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Sheave Diameter 26” (66 cm)
Cable Stretch Coeffcient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

0.474” (12.0mm) 7-CONDUCTOR, EXTRA HIGH STRENGTH 7H47–EHS ELECTRICAL


Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance 1.1 Ω/Kft (3.6 Ω/Km)

0.474” (12.0mm) 7-CONDUCTOR, EXTRA HIGH STRENGTH 7H47–EHS MECHANICAL


Cable Breaking Strength
Ends Fixed
24,500 lbs (109 KN) Nominal
Maximum Suggested Working Tension 12,250 lbs (55 KN)
Number and Size of Wires
Inner Armor 18 x 0.0470” (1.194 mm)
Outer Armor 18 x 0.0655” (1.664 mm)
Average Wire Breaking Strength
Inner Armor 542 lbs (2.4 KN)
Outer Armor 1,054 lbs (4.7 KN)

Cable Type Core Description Cable Weight
  Temp
Rating
°F
°C
Plastic
Type
Insulation
Thickness
in
mm
Copper
Construction
in
mm
Res.
Typical
Ω/Kft
Ω/km
Cap.
Typical
pf/ft
pf/m
O.D.
Each
in
mm
Type in
Air
in
H2O
lbs/Kft
Kg/Km
7H47RP-EHS 300
149
Poly 0.023
0.58
7x0.0128
7x0.325
9.8
32.2
46
151
0.084
2.13
Dacron 372
554
308
458
7H47RXZ-EHS 420
216
Camtane
ETFE
0.0115
0.292
0.0115
0.292
7x0.0128
7x0.325
9.8
32.2
48
157
0.061
1.549
0.084
2.134
Nomex 379
564
313
465
7H47RTZ-EHS 500
260
FEP
ETFE
0.0115
0.292
0.0115
0.292
7x0.0128
7x0.325
9.8
32.2
46
151
0.063
1.60
0.084
2.13
Nomex 392
583
326
485

The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
Core assembly – Conductors are bound with conductive tape and voids are flled with conductive fller and string.
Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68° F.
The temperature rating assumes a normal gradient for both temperature and weight.
Center conductor construction is 6x0.0142” with a non-conductive center member. The typical resistance is reduced by
approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
All values shown are nominal or typical values

Any cable inquiry please feel free to contact us.

Send Email
PREVIOUS:7J46 NEXT:7Q48-EHS

Any cable inquiry please feel free to contact us.