What is Instrumentation Cable


Instrumentation Cable are single or multi-pair/triple cables designed to carry signals. They are used for connecting instruments and electrical equipment especially in plants where process control is required, where transducer-generated signals are transmitted through to panels, controllers and other devices.The construction with individually shielded pair is typically used for analog signals and the construction with total shield only is used for digital signals.
 

Instrumentation Cable Specifications :


300V Type PLTC Shielded Instrumentation Cable Specifications


300V TYPE PLTC SHIELDED INSTRUMENTATION CABLE     
Item Size AWG    No. of Pairs
20-1PR Type PLTC Overall Shielded Instrumentation 300V 20 1 Pair
20-2PR Type PLTC Overall Shielded Instrumentation 300V 20 2 Pair
20-4PR Type PLTC Overall Shielded Instrumentation 300V 20 4 Pair
20-6PR Type PLTC Overall Shielded Instrumentation 300V 20 6 Pair
20-12PR Type PLTC Overall Shielded Instrumentation 300V 20 12 Pair
20-24PR Type PLTC Overall Shielded Instrumentation 300V 20 24 Pair
20-2PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 2 Pair
20-4PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 4 Pair
20-8PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 8 Pair
20-12PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 12 Pair
20-16PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 16 Pair
20-20PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 20 Pair
20-24PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 24 Pair
20-36PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 36 Pair
20-50PR Type PLTC Individual & Overall Shielded Instrumentation 300V 20 50 Pair
18-1PR Type PLTC Overall Shielded Instrumentation 300V 18 1 Pair
18-1Triad Type PLTC Individual & Overall Shielded Instrumentation 300V 18 1 Triad
18-2PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 2 Pair
18-3PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 3 Pair
18-4PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 4 Pair
18-6PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 6 Pair
18-8PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 8 Pair
18-12PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 12 Pair
18-24PR Type PLTC Individual & Overall Shielded Instrumentation 300V 18 24 Pair
16-1 Triad Type PLTC Individual & Overall Shielded Instrumentation 300V 16 1 Pair
16-2PR Type PLTC Individual & Overall Shielded Instrumentation 300V 16 2 Pair
16-4PR Type PLTC Individual & Overall Shielded Instrumentation 300V 16 4 Pair
16-6PR Type PLTC Individual & Overall Shielded Instrumentation 300V 16 6 Pair
 

TC Shielded Instrumentation Cable Specifications :

 
600V TYPE TC SHIELDED INSTRUMENTATION CABLE    
Item AWG Size No. of Pairs
18-1PR Type TC Overall Shielded Instrumentation 600V 18 1 Pair
18-1PR Type TC FR-EPR Overall Shielded Instrumentation 600V 18 1 Pair
18-1Triad Type TC Overall Shielded Instrumentation 600V 18 1 Triad
18-2 Triad Type TC Overall Shielded Instrumentation 600V 18 2 Triad
18-2PR Type TC Individual Overall Shielded Instrumentation 600V 18 2 Pair
18-2PR Type TC Overall Shielded Instrumentation 600V 18 2 Pair
18-4PR Type TC Individual Overall Shielded Instrumentation 600V 18 4 Pair
18-4PR Type TC Overall Shielded Instrumentation 600V 18 4 Pair
18-6PR Type TC Overall Shielded Instrumentation 600V 18 6 Pair
18-8PR Type TC Individual Overall Shielded Instrumentation 600V 18 8 Pair
18-12PR Type TC Indivdual Overall Shielded Instrumentation 600V 18 12 Pair
18-16PR Type TC Individual Overall Shielded Instrumentation 600V 18 16 Pair
18-36PR Type TC Individual Overall Shielded Instrumentation 600V 18 36 Pair
16-1PR Type TC Overall Shielded Instrumentation 600V 16 1 Pair
16-1PR Type TC FR-EPR Overall Shielded Instrumentation 600V 16 1 Pair
16-1 Triad Type TC-ER Overall Shield Tray Cable 600V 16 1 Triad
16-2PR Type TC Individual Overall Shielded Instrumentation 600V 16 2 Pair
16-2PR Type TC XLP/CPE Individual Overall Shielded Instrumentation 600V 16 2 Pair
16-2PR Type TC FR-EPR Individual Overall Shielded Instrumentation 600V 16 2 Pair
16-2PR Type TC FR-EPR Overall Shield Instr. Cable 600V 16 2 Pair
16-3PR Type TC Overall Shielded Instrumentation 600V 16 3 Pair
16-4PR Type TC Individual Overall Shielded Instrumentation 600V 16 4 Pair
16-4PR Type TC FR-EPR Individual Overall Shielded Instrumentation 600V 16 4 Pair
16-4PR Type TC FR-EPR Overall Shield Instrumentation Cable 600V 16 4 Pair
16-6PR Type TC Individual Overall Shielded Instrumentation 600V 16 6 Pair
16-6PR Type TC FR-EPR Individual Overall Shielded Instrumentation 600V 16 6 Pair
16-8PR Type TC Individual Overall Shielded Instrumentation 600V 16 8 Pair
16-8PR Type TC FR-EPR Individual Overall Shielded Instrumentation 600V 16 8 Pair
16-12PR Type TC Individual Overall Shielded Instrumentation 600V 16 12 Pair
16-12PR Type TC FR-EPR Individual Overall Shielded Instrumentation 600V 16 12 Pair
16-16PR Type TC Individual Overall Shielded Instrumentation 600V 16 16 Pair
14-2PR Type TC Individual Overall Shielded Instrumentation 600V 14 2 Pair
14-12PR Type TC Individual Overall Shielded Instrumentation 600V 14 12 Pair


Instrumentation Cable Conductors


A cable conductor consists of a wire or combination of wires that are not insulated from each other, and facilitate the passage of electric current through the cable.  Conductor-related specifications include material, size, and number of conductors
Conductor material includes various conductive metals.  Copper is the most widely used material, and features excellent corrosion resistance and high thermal conductivity, but relatively low strength-to-weight ratio.  Aluminum is less dense than copper, and is often used as a power conductor.  Cable conductors may also be made of steel and clad with an aluminum or copper shell.
Conductor size is measured in American Wire Gauge (AWG) in the United States.  The higher the gauge number, the smaller the diameter and thinner the wire.  Thicker wires have less resistance and are able to carry more current.  Outside of the U.S., conductors are measured in mm2.
Number of conductors is usually determined by the cable's application or intended use.
 

Instrumentation Cable Jacket and Insulation


Suppliers manufacture cable using a variety of jacket and insulation material in order to reduce the leakage of current from the conductor.  The cable's application is an important consideration when selecting insulation material. 
Ethylene Propylene Diene Elastomer (EPDM) provides excellent flexibility over a wide temperature range.
Neoprene is a synthetic rubber well-suited to chemical applications.  It is resistant to oil, flames, and chemicals.
Silicon rubber provides superior flexibility but lacks toughness and fluid resistance.
 

Instrumentation Cable Shielding


Control and instrumentation cables may feature a type of electromagnetic shielding material, which is wrapped around the cable underneath the outer jacket.  Shielding serves to prevent electrical noise from affecting the transmitted signal, and to reduce electromagnetic radiation emission from the cable itself.  Shielding is typically comprised of metal braiding, metal tape or foil braiding.  A shielded cable assembly may also feature a special grounding wire known as a drain wire. 

Instrumentation Cable why choose HuaDong?


Huadong Cable Group as a special Instrumentation Cable factory in China, We not only have over 30 years of production experience and 15 years of export experience in Instrumentation Cable, but also we have 15 senior engineers, they can free design the Instrumentation Cable size according to client’s requirement. Our Instrumentation Cable export such as South Africa, Philippines, Indonesia, Malaysia, Singapore, Vietnam, Korea, Mongolia, Yemen, Cambodia, Thailand, Kenya, Tanzania, UAE, Botswana,Nigeria, Panama, Iran etc.High quality service and production are the first choice of many customers.

Any cable inquiry please feel free to contact us.

Send Email

Bare Conductor

Any cable inquiry please feel free to contact us.