7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 PROPERTIES
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 14” (36 cm)
Cable Stretch Coeffcient: 2.7 ft/Kft/Klbs (3.0 m/Km/5KN)
	7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 ELECTRICAL
Maximum Conductor Voltage: 1,200 VDC
Conductor AWG Rating: 18
Minimum Insulation Resistance: 1,500 Mega Ω/Kft @ 500VDC (457 Mega Ω/Km @ 500VDC)
Armor Electrical Resistance: 16.0 Ω/Kft (52.5 Ω/Km)
	7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 MECHANICAL
Cable Breaking Strength
Ends Fixed: 4,700 lbs (20.9 KN) Nominal
Maximum Suggested Working Tension: 2,350 lbs (10.5 KN)
Number and Size of Wires
Inner Armor: 15 x 0.0243” (0.617 mm)
Outer Armor: 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength
Inner Armor : 111 lbs (0.50 KN)
Outer Armor : 242 lbs (1.10 KN)
	
		
	
	
		
			| Cable Type | Core Description | Cable Weight | 
		
			|  | Temp Rating
 °F
 °C
 | Plastic Type
 | Insulation Thickness
 in
 mm
 | Copper Construction
 in
 mm
 | Res Typical
 Ω/Kft
 Ω/Km
 | Cap. Typical
 pf/ft
 pf/m
 | O.D. Each
 in
 mm
 | in Air
 | in H2O
 | 
		
			| lbs/Kft Kg/Km
 | 
		
			| 1K22SA-S75 | See Below
 | PFA | 0.0305 0.775
 | 7x0.0159 7x0.404
 | 6.7 22.0
 | 43 141
 | 0.108 2.743
 | 95 142
 | 78 117
 | 
	
 Insulation is rated to 500°F. Armor wires are rated to 325° F at low exposure to H2S + CO2.
The armor wires are made of a corrosion resistant alloy steel. Wires are preformed.
The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F.
Voids in the copper strand are flled with a water-blocking agent to reduce water and gas migration.
SUPERSEAL, a special pressure seal agent, is applied between armor layers.
The insulation temperature rating assumes a normal gradient for both temperature and weight.
All values shown are nominal or typical values.